Description:
20-0326 Rubber protective boot for GX-6000, black
49-1619 Battery pack, Li-Ion, BUL-6000 for GX-6000
80-0006-03P Hose, 3’ for GX-6000, Teflon lined with probe attached
115 VAC Charger
Padded carrying case
Made In USA
The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.
The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.
Sensors available: CL2, CO, CO2, HCN, H2S, NH3, NO2, PH3, SO2, and VOC (volatile organic compounds)
6 Operating Modes
- Normal Mode
- Barhole Mode
- Inert Mode
- Leak Check
- Snap Log Mode
- Benzene Specific
The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.
The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.
Sensors available: CL2, CO, CO2, HCN, H2S, NH3, NO2, PH3, SO2, and VOC (volatile organic compounds)
SEE OUR OTHER LISTSINGS FOR THE VARIOUS GX-6000 CONFIGURATIONS
Sample Draw with PID, IR, O2, CO, H2S, VOC and Super Toxic Sensor Options
- 5 Operating modes
- Smallest 6 gas sample draw
- 2 Interchangeable smart sensor slots
- 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
- PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
- Benzene specific version
- PPM Leak Check mode
- LEL sensor protection mode
- Man-down alarm
- Panic alarm • Auto display rotation
- Peak-bar display
- LED Light source
- Internal sample pump
- Light weight, small, rugged IP-67
- Interchangeable battery packs
- Operates up to 14 hours
- Field replaceable sensors, batteries, filters and pump
- Intrinsically safe ATEX / IECEx / cCSAus
-
Gases & Detectable Ranges
|
Gas |
Measuring Range |
Reading Increment |
Alarm Set Points |
Accuracy (which ever is greater) |
PID Sensors |
10.6 Lamp |
600 VOC’s |
0 – 50,000 ppb |
1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) |
A1: 5,000 ppb |
± 10% of reading, ± 1 digit |
A2: 10,000 ppb |
0 – 6,000 ppm |
0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) |
A1: 400 ppm |
A2: 1,000 ppm |
10.0 Lamp |
Benzene Specific |
0.1 – 50 ppm |
0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) |
No Alarms |
300 VOC’s |
0 – 100 ppm |
0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) |
A1: 5 ppm A2: 10 ppm |
11.7 Lamp |
High Voltage Lamp |
0 – 1000 ppm |
0.1 ppm |
A1: 400 ppm |
A2: 1,000 ppm |
Galvanic |
Oxygen (O2) |
0 – 40.0% Vol. |
0.1% Vol. |
A1: 19.5 Vol. |
± 0.5% O2 |
A2: 23.5 Vol. |
Electro Chemical |
Carbon Monoxide (CO) |
0 – 500 ppm |
1 ppm |
A1: 25 ppm |
± 5% of reading or ± 5 ppm |
A2: 50 ppm |
TWA 25 ppm |
STEL 200 ppm |
Hydrogen Sulfide (H2S) |
0 – 100.0 ppm |
0.5 ppm |
A1: 5.0 ppm |
± 5% of reading or ± 2 ppm |
A2: 30.0 ppm |
TWA 1.0 ppm |
STEL 5.0 ppm |
Toxics (EC Sensors)
|
Ammonia (NH3) |
0 – 400.0 ppm |
0.5 ppm |
A1: 25 ppm |
± 10% of reading or ± 5% of full scale |
A2: 50 ppm |
Chlorine (Cl2) |
0 – 10.00 ppm |
0.05 ppm |
A1: 0.5 ppm |
A2: 1.0 ppm |
Hydrogen Cyanide (HCN) |
0 – 15.0 ppm |
0.1 ppm |
A1: 5 ppm |
A2: 10 ppm |
Nitrogen Dioxide (NO2) |
0 – 20.00 ppm |
0.05 ppm |
A1: 3 ppm |
A2: 6 ppm |
Sulfur Dioxide (SO2) |
0 – 99.90 ppm |
A1: 2 ppm |
A2: 5 ppm |
IR Sensors |
Carbon Dioxide (CO2) |
0 – 10,000 ppm |
20 ppm |
A1: 5,000 ppm |
± 5% of reading or ± 2% of full scale |
TWA 5,000 ppm |
0 – 10.00% Vol. |
0.02% |
A1: 0.50% Vol |
A2: 3.00% Vol |
STEL 3.00% Vol |
TWA 0.50% Vol |
Methane (CH4) |
0 – 100% LEL 0 – 100% Vol. |
1% LEL/ 0.5% Vol |
A1: 10% LEL A2: 50% LEL |
Hydrocarbons |
0 – 100% LEL 0 – 30% Vol. |
Catalytic |
Hydrocarbons (CH4, std) |
0 – 100% LEL |
1% LEL |
A1: 10%LEL |
± 5% of reading or ± 2% LEL |
A2: 50%LEL |
Common Specifications
|
Alarm Types |
Gas alarm |
Man-down |
Trouble |
Low and high adjustable |
1st – self reset 2nd – latching |
Low flow Sensor connection Low battery Circuit error Calibration range |
Sample Method |
Sample draw pump, flow rate 0.45 LPM, 50 foot sample range |
Display |
Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases |
Audible Alarm |
95 dB at 1 ft. |
Languages |
English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian |
Continuous Operation |
14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack) |
Operating Temp. & Humidity |
-4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing |
Dimensions |
2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack) |
Case Material |
Dust and water resistant with IP-67 approval (exclude sample hose and probe) |
Safety Design / Approvals
|
Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking |
Standard Features
|
2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode |
Standard Accessories |
• Rubber boot • Belt clip • Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions) |
Optional Accessories |
• SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable |
Warranty |
Two years material (including sensors) and workmanship. One year for PID sensor (Two months for 11.7 eV lamp) |