iEvac Elmridge EPB-900 Smoke Fire Toxic Gas Escape Hood No Sales Tax!
The iEvac EBP-900 $229.97 No Sales Tax and Free Shipping! Smoke Mask/Fire Escape Hood is the only smoke/fire evacuation hood certified to the American Standard ASTM E2952. Years of research and testing went into creating the iEvac, the most technologically advanced escape mask on the market today. NO SALES TAX ANYWHERE! Even better prices for large volume orders, call us! 1-800-485-1338
The iEvac Protects Against
- Carbon Monoxide
- Hydrogen Sulfide
- Additional Toxic Gases: sarin, smoke, hydrogen cyanide, chlorine, ammonia, sulfur dioxide, tear gas, OC, and more
-
Harmful Particulates: soot, fumes, aerosols, and others
- Contains a Pleated HEPA filter filter that removes sub-micron particles such as ebola, anthrax, ricin, smallpox, and radioactive particles
- Life-Threatening Physical Hazards: flammability and radiant heat
iEvac is currently being used nationwide by federal, state, local government agencies, all branches of the military, Fortune 500 companies, transit authorities, sporting arenas, marine, aviation, hospitals, homeowners and more.
iEvac has also achieved overwhelming acceptance internationally for its groundbreaking technological advantages and is currently being used in over 40 countries.
Features
- Maintenance-free
- At 9.5 in. (240mm) can withstand up to 1700°F (927°C) in radiant heat
- Dual filters for easier breathing
- Improved field of view compared with single filter in front
- Hood is a clear material resulting in an unobstructed field of view
- High visibility reflective strips for easy recognition
- Highest level of protection maintained by silicone neck dam
- Protects lungs, head, eyes, and face
- Can be used with eyeglasses, beards, and long hair
- Packaged in puncture-proof and waterproof laminate barrier
- Quick and easy donning
- Latex-free
- One universal size
Designated as a Qualified Anti-Terrorism Technology by the U.S. Department of Homeland Security, Office of the Safety Act.
The first and only hood Certified to the American National Standard for Smoke Escape Devices – Respiratory Protective Smoke Escape Device (RPED).
The U. S. Consumer Products Safety Commission states about escape masks “Emergency escape masks have the potential to reduce consumer-related deaths and injuries by assisting in egress from fires, provided they perform effectively and reliably.”
Performance and Protection Capability Tests beyond the Requirements of American Standard
Tested by US Army Research, Development and Engineering Command, Edgewood Chemical Biological Center
Function | Test Condition | Requirement | Result |
Overall protection factor | Test subjects performing standard OSHA exercises inside the fit test chamber at Edgewood | 2,000 | > 90,000 |
Protection factor inside the hood but outside the nose cup | Test subjects performing standard OSHA exercises inside the fit test chamber at Edgewood | 150 | > 8,000 |
Tested and Certified to American Standard: Physical Properties
Challenge | Test Condition | Duration | Result |
Radiant heat | Within 9.5 inches (240 mm) of heating panel between 980 and 1700°F (527 and 927°C) | 15 secs repeated | pass |
Flammability | 9.8 inches (250 mm) away from a burner flame of 1475°F (800°C) | One rotation | pass |
Molten drip | Molten polypropylene rod drip | Each location | pass |
Inhalation temperature | CO at 77°F (25°C) and 87%RH | 15 mins | pass |
Fogging | Read eye chart from 20 feet (6.1 meters) at the 20/100 line | 5 mins | pass |
Field of vision | Apertometer headform | viewing | pass |
Light transmission | Haze of vision area | left and right | pass |
Temperature variation | 32°F (0°C) followed by 158°F (70°C) | 24 hours each | pass |
Pressure variation | Ambient to 4.4 psi (300 mbar) below | 1,000 cycles | pass |
Vibration | 0.75 inches (19 mm) at 100 rpm | 10,000 cycles | pass |
Corrosion | Salt spray at 95°F (35°C) then 72°F (22°C ) at 50% RH | 48 hours each | pass |
Puncture and tear | 3.5 oz (100 grams) striker dropped from 4 inches (100 mm) | Ready to use | pass |
Water leakage | Immerse in water at 160°F (70°C) to depth of 24 inches | 5 mins | pass |
Tested and Certified to American Standard: Hood Performance Tests
Function | Test Condition | Duration | Requirement | Result |
Speed of donning | Remove from pack and wear properly | Less than 30 secs | < 30 secs | pass |
Total inward leakage | Test subjects performing standard exercises | 2.5 mins | < 2% | <0.01% |
Ocular leakage | Test subjects performing standard exercises | 2.5 mins | < 20% | <0.1% |
Carbon dioxide build-up | Breathing machine | 25 cycles per min | < 2.5% | < 1.7% |
Breathing resistance | Probed headform with breathing machine | 30 cycles | -3.2 in (-81.5 mm) +1.2 in (+30.6 mm) | pass |
Soot particulate | Inhalation breathing resistance with 200 mg/m3 soot | 5 mins | < 8 in (< 204 mm) | pass |
Soot particulate | Exhalation breathing resistance with 200 mg/m3 soot | 5 mins | < 6 in (< 153 mm) | pass |
Tested and Certified to American Standard: Gas and Particulate Tests
Challenge | Symbol | Type | Concentration ppm | Requirement | Result |
Carbon monoxide | CO | Hazardous combustion by-product | 3,000 | 15 mins | > 45 mins |
Carbon monoxide | CO | Hazardous combustion by-product | 5,000 | 15 mins | > 46 mins |
Hydrogen cyanide | HCN | Hazardous combustion by-product | 400 | 15 mins | > 90 mins |
Hydrogen chloride | HCl | Acid gas toxic industrial chemical | 1,000 | 15 mins | > 70 mins |
Sulfur dioxide | SO2 | Acid gas toxic industrial chemical | 100 | 15 mins | > 70 mins |
Cyclohexane | C6H12 | Organic vapor toxic industrial chemical | 500 | 15 mins | > 41 mins |
Acrolein | C3H4O | Organic vapor toxic industrial chemical | 100 | 15 mins | > 65 mins |
Dioctyl phthalate | DOP | Particulate aerosol 0.185 micron | 200 mg/m3 | >95% | > 99.996% |
Additional Gas and Particulate Tests
Challenge | Symbol | Type | Concentration ppm | Requirement | Result |
Carbon monoxide | CO | Hazardous combustion by-product | 10,000 | 15 mins | > 30 mins |
Dioctyl phthalate | DOP | HEPA filtration test for particulates and aerosols | 200 mg/m3 | > 99.97% | > 99.996% |
Ammonia | NH3 | Toxic industrial gas | 1,250 | 15 mins | > 60 mins |
Formaldehyde | HCHO | Toxic industrial gas | 250 | 15 mins | > 60 mins |
Phosgene | COCl2 | Toxic industrial gas | 125 | 15 mins | > 60 mins |
Phosphine | PH3 | Toxic industrial gas | 150 | 15 mins | > 60 mins |
Chlorine | Cl2 | Toxic industrial gas | 200 | 15 mins | > 60 mins |
DMMP | DMMP | Simulant for sarin nerve gas | 1,000 | 15 mins | > 60 mins |
Tear Gas | CS | tear gas | 3 | >> 8 hours | > 8 hours |
Tear Gas | CN | tear gas | 16 | >> 8 hours | > 8 hours |
Hydrogen sulfide | H2S | Acid gas toxic industrial chemical | 1,000 | 15 mins | > 600 mins |
Hydrogen sulfide | H2S | Acid gas toxic industrial chemical | 5,000 | 15 mins | > 85 mins |
Hydrogen sulfide | H2S | Acid gas toxic industrial chemical | 10,000 | 15 mins | > 40 mins |
Hydrogen sulfide | H2S | Acid gas toxic industrial chemical | 20,000 | 15 mins | > 20 mins |