RKI Instruments 81-SDM3R104 SDM-3R calibration station GX-3R/GX-3R Pro

RKI Instruments 81-SDM3R104 SDM-3R calibration station for GX-3R / GX-3R Pro

$1,571.97
Description

RKI Instruments 81-SDM3R104 $1,571.97 Free Shipping. No State or Local Sales Tax Anywhere! SDM-3R calibration station for GX-3R / GX-3R Pro

With 1 solenoid, demand flow regulator, 34AL cyl H2S/CO/CH4/O2, cylinder holder, AC adapter, flash drive,

USB cable, and tubing

Stand Alone Use (no PC required)

  • Compatible with both GX-3R and GX-3R Pro
  • Automatically charge, bump test, and/or calibrate
  • Auto on/off of gas detector
  • 3 separate gas inputs
  • Multiple modules (10 max) can use one set of calibration equipment
  • Save Bump Test, Calibration, and Alarm Check records to USB flash drive, computer, or network
  • Includes PC software for viewing/archiving bump test, calibration records, and event data

PC-Controlled Use

  • Multiple modules connected to a PC (10 max)
  • Automatic calibration/bump test option
  • Configure GX-3R (Pro) parameters
  • Archive Bump Test, Calibration, and Alarm Check
  • Archive data to network location
  • Software controlled data retrieval
  • Windows 7, 8, and 10 compatible

Stand Alone Use
The SDM-3R is a versatile maintenance tool that automates the service of a GX-3R (Pro) portable gas monitor. This docking station can be used as a stand alone device for charging, calibration and bump testing, with all records stored automatically for future upload to a PC via USB flash drive (PC software and flash drive included).

PC-Controlled Use
Automate how you manage and service GX-3R (Pro) instruments by connecting the SDM-3R to a computer with a USB cable. With the SDM Docking Station controller software, you can simultaneously calibrate, bump test, alarm check, archive data, or charge up to ten instruments. You can also download the datalogging history from each instrument into one easy to manage location. SDM-3R stations can be manifolded together to reduce the number of demand flow regulators gas cylinders required.

Specifications

Input Power

AC Adapter with 100 – 240 VAC, 47-63 Hz, 0.4A input and 5.99 VDC, 2A output provided as standard.

Environmental Conditions

For Indoor Use Only

0° C to 40° C, below 95% Relative Humidity, Non-Condensing

Applicable Instruments

GX-3R and GX-3R Pro

Maximum Number of

Records Saved

Stand Alone: 200 calibrations, or 214 bump test, or 469 alarm check records
PC program Controlled: Unlimited records

5 Ports

3 Calibration gas, 1 fresh air and 1 exhaust

Standard Accessories

  • AC Adapter
  • USB Flash Drive
  • Inlet Air Filter
  • 10 Foot Long Exhaust Tube
  • One 3 Foot Long Tube for GAS Fitting
  • USB Cable, Type A to Type B

Why Choose Us

Free Shipping

Free Shipping

Free Shipping on most products

In Business for 45 Years

In Business for 45 Years

We have been helping protect since 1978!

Chat With Us

Chat With Us

We offer 24-hour automated chat support

No Sales or Local Tax

No Sales or Local Tax

We don't charge any Sales or Local Tax