RKI 72-6XBX-C    GX-6000 for VOC’s (0 - 6,000 ppm PID, 10.6 eV lamp) with Li-Ion battery pack and 115 VAC charger, rubber protective boot, 3' teflon lines hose with probe attached  No Sales Tax  Free shipping RKI factory to you  Authorized worldwide RKI distributor
 

GX-6000 Instrument Price Also Includes
Part# Description
20-0326 Rubber protective boot for GX-6000, black
49-1619 Battery pack, Li-Ion, BUL-6000 for GX-6000
80-0006-03P Hose, 3’ for GX-6000, Teflon lined with probe attached
Made In USA

The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.

The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.

Sensors available: CL2, CO, CO2, HCN, H2S, NH3, NO2, PH3, SO2, and VOC (volatile organic compounds)

6 Operating Modes

  • Normal Mode
  • Barhole Mode
  • Inert Mode
  • Leak Check
  • Snap Log Mode
  • Benzene Specific

The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.

The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.

Sensors available: CL2, CO, CO2, HCN, H2S, NH3, NO2, PH3, SO2, and VOC (volatile organic compounds)

SEE OUR OTHER LISTSINGS FOR THE VARIOUS GX-6000 CONFIGURATIONS

Sample Draw with PID, IR, O2, CO, H2S, VOC and Super Toxic Sensor Options

  • 5 Operating modes
  • Smallest 6 gas sample draw
  • 2 Interchangeable smart sensor slots
  • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
  • PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
  • Benzene specific version
  • PPM Leak Check mode
  • LEL sensor protection mode
  • Man-down alarm
  • Panic alarm • Auto display rotation
  • Peak-bar display
  • LED Light source
  • Internal sample pump
  • Light weight, small, rugged IP-67
  • Interchangeable battery packs
  • Operates up to 14 hours
  • Field replaceable sensors, batteries, filters and pump
  • Intrinsically safe ATEX / IECEx / cCSAus
  • Gases & Detectable Ranges

    Gas Measuring Range Reading Increment Alarm Set Points Accuracy (which ever is greater)
    PID Sensors
    10.6 Lamp 600 VOC’s 0 – 50,000 ppb 1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) A1: 5,000 ppb ± 10% of reading, ± 1 digit
    A2: 10,000 ppb
    0 – 6,000 ppm 0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) A1: 400 ppm
    A2: 1,000 ppm
    10.0 Lamp Benzene Specific 0.1 – 50 ppm 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) No Alarms
    300 VOC’s 0 – 100 ppm 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) A1: 5 ppm A2: 10 ppm
    11.7 Lamp High Voltage Lamp 0 – 1000 ppm 0.1 ppm A1: 400 ppm
    A2: 1,000 ppm
    Galvanic
    Oxygen (O2) 0 – 40.0% Vol. 0.1% Vol. A1: 19.5 Vol. ± 0.5% O2
    A2: 23.5 Vol.
    Electro Chemical
    Carbon Monoxide (CO) 0 – 500 ppm 1 ppm A1: 25 ppm ± 5% of reading or ± 5 ppm
    A2: 50 ppm
    TWA 25 ppm
    STEL 200 ppm
    Hydrogen Sulfide (H2S) 0 – 100.0 ppm 0.5 ppm A1: 5.0 ppm ± 5% of reading or ± 2 ppm
    A2: 30.0 ppm
    TWA 1.0 ppm
    STEL 5.0 ppm
    Toxics (EC Sensors)
    Ammonia (NH3) 0 – 400.0 ppm 0.5 ppm A1: 25 ppm ± 10% of reading or ± 5% of full scale
    A2: 50 ppm
    Chlorine (Cl2) 0 – 10.00 ppm 0.05 ppm A1: 0.5 ppm
    A2: 1.0 ppm
    Hydrogen Cyanide (HCN) 0 – 15.0 ppm 0.1 ppm A1: 5 ppm
    A2: 10 ppm
    Nitrogen Dioxide (NO2) 0 – 20.00 ppm 0.05 ppm A1: 3 ppm
    A2: 6 ppm
    Sulfur Dioxide (SO2) 0 – 99.90 ppm A1: 2 ppm
    A2: 5 ppm
    IR Sensors
    Carbon Dioxide (CO2) 0 – 10,000 ppm 20 ppm A1: 5,000 ppm ± 5% of reading or ± 2% of full scale
    TWA 5,000 ppm
    0 – 10.00% Vol. 0.02% A1: 0.50% Vol
    A2: 3.00% Vol
    STEL 3.00% Vol
    TWA 0.50% Vol
    Methane (CH4) 0 – 100% LEL 0 – 100% Vol. 1% LEL/ 0.5% Vol A1: 10% LEL A2: 50% LEL
    Hydrocarbons 0 – 100% LEL 0 – 30% Vol.
    Catalytic
    Hydrocarbons (CH4, std) 0 – 100% LEL 1% LEL A1: 10%LEL ± 5% of reading or ± 2% LEL
    A2: 50%LEL

    Common Specifications

    Alarm Types Gas alarm Man-down Trouble
    Low and high adjustable 1st – self reset 2nd – latching Low flow Sensor connection Low battery Circuit error Calibration range
    Sample Method Sample draw pump, flow rate 0.45 LPM, 50 foot sample range
    Display Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
    Audible Alarm 95 dB at 1 ft.
    Languages English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
    Continuous Operation 14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack)
    Operating Temp. & Humidity -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
    Dimensions 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack)
    Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
    Safety Design / Approvals Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking
      Standard Features 2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode
    Standard Accessories • Rubber boot • Belt clip • Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions)
    Optional Accessories • SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable
    Warranty Two years material (including sensors) and workmanship. One year for PID sensor (Two months for 11.7 eV lamp)
  • If you need a configuration or any RKI product or accessory not shown on this site, just let us know and we will add it

    LIFE PROTECTORS AND SHEPARD SAFETY PRODUCTS IS AN AUTHORIZED WORLDWIDE FULL DISTRIBUTOR FOR ALL RKI PRODUCTS.  UNITS AND SENSORS HAVE A SHELF LIFE SO WE DO NOT STOCK AND WAIT FOR ORDERS.  YOUR ORDERS ARE SENT TO RKI IMMEDIATELY SO THEY CAN SHIP DIRECTLY TO YOUR DOOR. THAT WAY YOU WILL ALWAYS RECEIVE THE FRESHEST ITEMS. THESE ARE LIFE SAVING DEVICES AND WE WOULD DO IT NO OTHER WAY.  IF ANY QUESTIONS PLEASE DO NOT HESITATE TO CONTACT US.