Skip to content
HUGE Discounts on Non-Contact Voltage Detectors by Enespro until the end of October!
HUGE Discounts on Non-Contact Voltage Detectors by Enespro until the end of October!

Country

LAKELAND INT640WB Interceptor Plus Level A Encapsulated Suit

Original price €857,95 - Original price €974,95
Original price
€857,95
€857,95 - €974,95
Current price €857,95

Lakeland INT640WB Interceptor Plus Fully Encapsulated | $879.97 | Level A Suit No Sales Tax and Free Shipping from Lakeland.  

Level A, Front Entry, Wide View Face Shield.  Interceptor Plus the ultimate in chemical protection with the most extensive chemical data in the industry. Gas-Tight and Vapor-Tight with a Wide View Face Shield.

INT640WB Fully encapsulated front entry vapor-protective suit (Level A),
expanded back, sealed seams inside and out, 48" zipper, double
storm flap with hook and loop, 2 layer "wide-view" faceshield (10
mil Teflon/40 mil PVC), Anti-Reversing Butyl and North silver
shield glove system, 2 exhaust valves, attached sock boots with
boot flaps, 1.5" waist belt with 3 belt loops sewn (inside) and
sealed. Storage bag included.

Fentanyl: Protection for First Responders and Law Enforcement
Due to the Fentanyl opioid crisis the risk of exposure to law enforcement, first responders, medical and prison personnel is extremely high. 

Features: Front entry vapor-protective Level A suit, Wide-vision Visor

INT640WB Case Size1/case
SeamHeat Sealed PlusMaterials: Proprietary film; Needle punch PET; EVOHPermaSURE: Determine safe-use times and model the effects of temperature change on permeation rates for over 4000 chemicalsInterceptor Plus Physical Properties
Physical Property Test Method Units Test Results
Basic Weight ASTM D3776 oz/sy 11
Grab Tensile MD ATSM D5034 pounds 218.5
Grab Tensile XD ASTM D5034 pounds 170.4
Trapexoidal Tear MD ASTM D5733 pounds 34.7
Trapexoidal Tear XD ASTM D5733 pounds 38.7
Ball Burst ASTM D751

Interceptor® Plus Permeation Data
Challenge Chemical CAS Number Physical State Normalized Breakthrough Time
1,3-Butadiene 106-99-0 Liquid >480
2,2,2-Trichloroethanol 115-20-8 Liquid >480
2,3 Dichloro- 1Propene 78-88-6 Liquid >480
2,4-Dichlorophenol 120-83-2 Liquid >480
2,4-dichlorophenoxy Acetic Acid 94-75-7 Liquid >480
4-Bromofluorobenzene 460-00-4 Liquid >480
Acetic Acid 64-19-7 Liquid >480
Acetone 67-64-1 Liquid >480
Acetonitrile 75-05-8 Liquid >480
Acetyl Chloridein 75-36-5 Liquid >480
Acrolein 107-02-8 Liquid >480
Acrylic Acid 79-10-7 Liquid >480
Acrylonitrile 107-13-1 Liquid >480
Allyl Chloride 107-05-1 Liquid >480
Ammonia 7664-41-7 Liquid >480
Ammonium Fluoride 12125-01-8 Liquid >480
Bromine 7726-95-6 Liquid 98
Carbon Disulfide 75-15-0 Liquid >480
Chlorine 7782-50-5 Gas >480
Dichloromethane 75-09-2 Liquid >480
Diethylamine 109-89-7 Liquid >480
Dimethylformamide 68-12-2 Liquid >480
Ethyl Acetate 141-78-6 Liquid >480
Ethylene Oxide 75-21-8 Gas >480
Hexane 110-54-3 Liquid >480
Hydrofluoric Acid 7664-39-3 Liquid >480
Hydrogen Chloride 7647-01-0 Gas >480
Hydrogen Fluoride 7664-39-3 Gas >480
Methanol 67-56-1 Liquid >480
Methyl Chloride 74-87-3 Gas >480
Nitrobenzene 98-95-3 Liquid >480
Phosphorus Pentachloride 10026-13-8 Liquid >480
Sodium Hydroxide 1310-73-2 Liquid >480
Sodium Hydroxide 1310-73-2 Liquid >480
Sulfuric Acid 7664-93-9 Liquid >480
Sulphur Dioxide 7446-09-5 Gas >480
Sulphuryl Chloride 7791-25-5 Liquid >480
Tetrachloroethylene 127-18-4 Liquid >480
Tetrahydrofuran 109-99-9 Liquid >480
Thionyl Chloride 7719-09-7 Liquid 90
Toluene 108-88-3 Liquid >480
Vinyl Chloride 75-01-4 Liquid >480
Vinyl Chloride 75-01-4 Liquid >480
PCB (Transformer Oil) PCB Liquid >480
Carbon Tetrachloride 56-23-5 Liquid >480
Cresol 95-48-7 Liquid >480
Epichlorohydrin 106-89-8 Liquid >480
Trimethyl Phosphate 512-56-1 Liquid >480

Note: Chemical Resistance Data is in accordance with ASTM F-739 test method. Testing is performed on fabric samples only, not finished garments. Sources for all test