Skip to content
HUGE Discounts on Non-Contact Voltage Detectors by Enespro until the end of October!
HUGE Discounts on Non-Contact Voltage Detectors by Enespro until the end of October!

Country

MSA 10154079 Altair 2X Single Gas Detector NH3 | No Sales Tax and Free Shipping

Save 14% Save 14%
Original price Dhs. 3,725.00
Original price Dhs. 3,725.00 - Original price Dhs. 3,725.00
Original price Dhs. 3,725.00
Current price Dhs. 3,207.00
Dhs. 3,207.00 - Dhs. 3,207.00
Current price Dhs. 3,207.00

MSA 10154079 Altair 2X Single Gas Detector NH3 | $859.97 No Sales Tax and Free Shipping

ALTAIR® 2X, NH3 (25, 50), Charcoal

Part Number:

10154079

Length:

54.000 MM (2.126 IN)

Width:

60.000 MM (2.362 IN)

Height:

88.000 MM (3.465 IN)

Weight:

0.110 KG (0.243 LB)

 

 All ALTAIR 2X Gas Detectors

  • Incorporate proven XCell® sensor technology
  • Enhance worker safety, compliance and traceability
  • Minimize cost of ownership
  • Demonstrate rugged durability

 

Product Options

  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S  -
    • Features the first stand-alone bump test, which eliminates the need for bottled gas!
    • Bump test anytime, anywhere
    • Based on proven science and patented sensor capabilities
  • ALTAIR 2XP Gas Detector with XCell Pulse Technology: H2S
  • ALTAIR 2X Gas Detectors: CO, CO-HC (High Concentration), CO-H2 (Hydrogen Resistant), H2S-LC, SO2, NO2, NH3 and Cl2
  • ALTAIR 2XT Two-Tox Gas Detector: CO/H2S, CO-H2/H2S, CO/H2S-LC, CO/NO2 and SO2/H2S-LC

HIGHLIGHTS

Low cost of ownership

  • Fastest sensor response times, lowest calibration gas flow rate on the market
  • > 4-year expected sensor life
  • 3-year warranty on instrument & most sensors (2 years on Cl2, NH3)
  • Stand-alone bump tests reduce maintenance, increase productivity (ALTAIR 2XP only)
  • 1 device can monitor 2 gases (ALTAIR 2XT only)

Increased safety awareness & compliance

  • Stand-alone bump test anytime, anywhere without specific calibration gas (ALTAIR 2XP only)
  • Bump pass: green LED flash every 15s, large on-screen checkmark
  • Bump fail or expiration: red LED flash every 15s, no checkmark
  • End-of-sensor-life warning and alarm

Full-time traceability

  • Records 75 alarm events
  • 150+ hours of periodic data (ALTAIR 2X and 2XP)
  • 100+ hours of periodic data (ALTAIR 2XT)
  • Compatible with MSA GALAXY® GX2 Automated Test System and MSA Grid

Rugged durability

  • Tough over-molded rubber armor
  • Survives multiple 25-ft drops onto concrete
  • Agency-certified dust- and water-tight IP67 construction
  • Intrinsically-safe design
  • Applications
  • Confined Space
  • Turnarounds & Plant Maintenance
  • Markets
  • Construction
  • Fire Service
  • General Industry
  • Oil & Gas
  • Utilities